1 / 9
Ubiquiti
Ubiquiti UniFi Access Retrofit Hub for Two Doors
MPN: UA-RETROFIT-HUB-2
$265.99
Out of stock. Request a quote for an ETA
Quantity
1
Total$265.99
Specification
General
Brand
Ubiquiti
Model
UA-Retrofit-Hub-2
Sales unit
1 unit
Manufacturer part number
UA-RETROFIT-HUB-2
Hardware
LEDs
W/B Learn More
Buttons
(1) Factory reset
(2) 12V/Dry/24V switch
Power Supply
DC 12/24V
Digital Input
(2) Third-party Wiegand Reader / UniFi Retrofit Reader
(2) Door exit request
(2) Door position
(1) Emergency
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Dry Output Relay
Lock: rated 30V DC, up to 1A
Aux: rated 30V DC, up to 1A
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Reader Power Output
12V DC, up to 0.5A
Networking Interface
(2) 10/100 MbE RJ45 ports
Powered Output Relay
12V Lock: 12V DC, up to 1A
24V Lock: 24V DC, up to 0.5A
Indoor and Outdoor Use
Indoor only
Max. Power Consumption
50W (4W without connected readers or locks)
CAN/ULC-60839-11-1 Grade
Grade assignment: I
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Ambient Operating Humidity
5 to 90% noncondensing
Ambient Operating Temperature
-10 to 40° C
(14 to 104° F)
Recommend Max. Cable Length / Other locks
(1A)
24 AWG length: 9 m (30 ft)
22 AWG length: 15 m (49 ft)
20 AWG length: 24 m (79 ft)
18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
Document number, and issue date and/or revision level
UA-Retrofit-Hub-2, V01
Recommend Max. Cable Length / UA-Lock-Electric
(400mA)
24 AWG length: 25 m (82 ft)
22 AWG length: 42 m (138 ft)
20 AWG length: 66 m (217 ft)
18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
Recommend Max. Cable Length / UA-Retrofit-Reader (250mA)
18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft)
Recommend Max. Cable Length / UA-Lock-Magnetic-270kg (800mA)
24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Recommend Max. Cable Length / UA-Lock-Magnetic-540kg (500mA)
24 AWG length: 20 m (66 ft)
22 AWG length: 32 m (105 ft)
20 AWG length: 51 m (167 ft)
18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
Overview
Dimensions
140 x 120 x 45 mm
(5.5 x 4.7 x 1.8")
Power Method
12/24V DC
UL 294 Level
Destructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
NDAA Compliant
Yes
Input Terminals
(2) Third-party Wiegand Reader / UniFi Retrofit Reader
(2) Door exit request
(2) Door position
(1) Emergency
Supported Doors
2
Maximum User Count
10,000
Software
Software Information
The software version can be checked at https://unifi.ui.com
Management Application
Access
Mechanical
Weight
420 g (14.8 oz)
Mounting
Din-rail (Included)
Mount Material
SGCC steel
Enclosure Material
Polycarbonate
Shipping
Shipping weight
1.35 lb
Shipping dimensions (L × W × H)
7.1 × 5.6 × 2.6 in
Product description
The UniFi Access Retrofit Hub adds entry and exit control for up to two doors while supporting existing Wiegand and OSDP readers. It requires 12V or 24V DC power. Readers, locks and the power source must be selected separately for the installation.